A propane tank holds liquid. Your generator burns vapor. The liquid has to boil off inside the tank first, and it takes its heat from the outside air through the tank wall. Two things slow that down: cold air and a low tank, because less liquid touches less steel.

When the tank cannot make vapor as fast as the engine burns it, pressure drops and the generator stumbles or shuts down, often with fuel still in the tank. It tends to happen at the worst moment: a long outage, deep cold and a tank that has been drawn down for days.

How much vapor a tank can supply

The propane industry's rule of thumb multiplies the tank's diameter by its length and by a factor for how full it is, then scales the result for temperature. These figures are for a tank that is 30% full.

Tank40°F (4°C)20°F (-7°C)0°F (-18°C)-10°F (-23°C)-15°F (-26°C)
120 gallon tank228,000228,000114,00057,00029,000
250 gallon tank395,000395,000197,00099,00049,000
320 gallon tank483,000483,000242,000121,00060,000
500 gallon tank630,000630,000315,000158,00079,000
1,000 gallon tank1,102,0001,102,000551,000276,000138,000

BTU per hour. A tank at 60% full supplies about 40% more than these figures; at 10% full, about a third less.

How much a generator needs

GeneratorAt a 3 kW household loadAt full outputSmallest tank that keeps up at full output, 0°F and 30% full
10 kW70,000135,000250 gallon tank
14 kW100,000267,000500 gallon tank
18 kW77,000263,000500 gallon tank
22 kW135,000339,0001,000 gallon tank
24 kW132,000339,0001,000 gallon tank
26 kW77,000361,0001,000 gallon tank
28 kW79,000363,0001,000 gallon tank

BTU per hour, from the makers' published burn rates.

What to do about it

The propane runtime calculator runs this check for your own tank, fill level and temperature.

See what this means for your own home and fuel.

Open the planner